Safety Label 41
Travis Industries 4040708 100-01160
The safety (listing) label is adhered to the base of the fireplace near the gas control valve. A copy of
the safety label is shown below.
Fireplace Xtrordinair 36 DV XL
Direct Vent
Vented Gas Fireplace Heater
Tested and certified by OMNI-Test Laboratories, Inc. to the combustion performance and construction requirements of ANSI
Z21.88a-2000 and applicable sections of UL 307b.
This appliance must be installed in accordance with local codes, if any; if none, follow National Fuel Gas Code ANSI Z223.1.
Installation in Manufactured or Mobile Homes must conform with Manufactured Home Construction and Safety Standard, Title 24
CFR, Part 3280.
This appliance is only for use with the type of gas indicated on this rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owners manual for details. This
appliance is not convertible for use with other gases, unless a certified kit is used.
Vented Gas Fireplace Heater. Not for use with Solid Fuel.
The 36 DV XL is designed to operate on natural gas, or propane (LPG). THIS APPLIANCE IS FACTORY SET FOR USE WITH
NATURAL GAS.
For conversion to Propane (LPG) use factory supplied kit. See owner’s manual for information on making these changes.
WARNINGS:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the information
in the owner’s and installation manual provided with this appliance. For assistance or additional information consult a qualified
installer, service agency or the gas supplier.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.
This vented gas fireplace heater is not for use with air filters.
CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other
liquids having flammable vapors away.
CAUTION: Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel should be done by a
licensed or qualified service person.
Only use direct vent systems listed in owner’s manual to vent this appliance to the exterior (direct discharge only without duct
connection).
This appliance must be properly connected to a vanting system in accordance with manufacturer’s installation instructions.
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in
carbon monoxide (CO) poisoning and possible death.
10850 117th Pl. N.E. Kirkland, WA 98033
FAN TYPE VENTED CIRCULATOR
Blower Electrical Rating: 115 V., 1.5 Amps, 60 Hz, 150 watts
L.P
.
N.G.
L.P
.
N.G.
Input Rate on “HI” (BTU/Hr)......... 43,000 43,000 Minimum Inlet Pressure (inches W.C.)............. 11.5” 5.5”
Input Rate on “LO” (BTU/Hr) ....... 22,600 29,000 Maximum Inlet Pressure (inches W.C.)............ 13” 7”
........................................................ Manifold Pressure on “HI” (inches W.C.) ........ 11” 3.5”
This appliance is equipped for installation in USA, 0-2000 ft. (0-610 m).
In USA, for altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner’s manual for information on making these changes.
Manufacture 2000 Jan. Apr. Jul. Oct.
Date: 2001 Feb. May Aug. Nov.
2002 Mar. Jun. Sep. Dec.
Report No. 028-S-20b-1
Minimum Clearances to Combustibles
Faceplate to Adjacent Wall . . . . . . . . . . . . 4-1/2” (115mm) Hearth Extension in Front - 16” (406mm), 0” (0mm) if Fireplace Raised 3” (76mm)
Wood Floor Beneath Fireplace . . . . . . . . 0” (0mm) Hearth Extension to Sides of Faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0” (0mm)
Back to enclosure (from stand-offs) . . . 0” (0mm) Sides to enclosure (from stand-offs). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0” (0mm)
Top to enclosure (from stand-offs) . . . . . 0” (0mm) Faceplate to 8” Deep Mantel - 22” (558mm) for Rectangular Faces, 24” (610mm) for Arched Faces*
Flue Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Owner’s Manual
* See Owner’s Manual For Additional Mantel Clearances and Options.