Montigo H34DF Guide d'installation

Naviguer en ligne ou télécharger Guide d'installation pour Foyers Montigo H34DF. Montigo H34DF Installation guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 22
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Check local codes
and read all
instructions prior to
installation.
Leave this manual
with the owner.
Gas Fireplace
H34D
Installation
Operation &
Maintenance
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Warning:
Improper installation, adjustment,
alteration, service or maintenance can
cause injury or property damage. Refer to
this manual. For assistance or additional
information consult a qualified installer,
service agency or the gas supplier.
For Your Safety:
Do not store or use gasoline
or other flammable vapors
and liquids in the vicinity of
this or any other appliance.
Vue de la page 0
1 2 3 4 5 6 ... 21 22

Résumé du contenu

Page 1 - Maintenance

Check local codesand read allinstructions prior toinstallation. Leave this manualwith the owner.Gas FireplaceH34DInstallationOperation &Mainten

Page 2 - Table Of Contents

Page 10H34D Gas FireplacePart No. XG0130InstallationFigure 20. Extended installation.Figure 21a. Corner installation.Figure 21b. Flex installation.Rea

Page 3

Page 11H34D Gas FireplacePart No. XG0130InstallationB. Multi-Elbow InstallationsFor more diffiicult installation situations, the H34D Rear Vent may be

Page 4

Page 12H34D Gas FireplacePart No. XG0130Finishing Around the FireplaceCombustible mantels and mouldings may be safely installed over the topand on the

Page 5

Page 13H34D Gas FireplacePart No. XG0130InstallationWiring for the optional Fan KitAll H34D fireplaces may be equipped with optional fan kits for cir

Page 6

Page 14H34D Gas FireplacePart No. XG0130InstallationLog 'D'Cautions: If logs are not placed properly, excessive sootingwill result. The su

Page 7

Page 15H34D Gas FireplacePart No. XG0130WARNING: If you do not follow these instructions exactly, a fire or explosionmay result causing property damag

Page 8

Page 16H34D Gas FireplacePart No. XG0130For Your Safety - READ BEFORE LIGHTING:To Turn Off Gas To Appliance:Lighting Instructions: If you cannot reac

Page 9

Page 17H34D Gas FireplacePart No. XG0130MaintenanceWARNING:Do not attempt to clean glass when hot.Do not clean glass with abrasive materials as anygla

Page 10

Page 18H34D Gas FireplacePart No. XG0130MaintenanceGas Control ValvePilot Burner Adjustment1. Locate Pilot Adjustment Screw. (See figure 30.)2. Adjus

Page 11

Page 19H34D Gas FireplacePart No. XG0130The WarrantyThe WarrantyThe WarrantyThe WarrantyThe WarrantyThe Companies warrants the Montigo Gas Appliance t

Page 12

Page 2H34D Gas FireplacePart No. XG0130IntroductionThank You for choosing a Montigo Gas Fireplace.About this Fireplace:The H34D is an 18,000 BTU firep

Page 13

Page 20H34D Gas FireplacePart No. XG0130Appendix A - Termination LocationsA = clearance to the termination frame above grade, veranda, porch, deck, or

Page 14

Page 21H34D Gas FireplacePart No. XG0130This appliance may be installed as an OEM installa-tion in a manufactured home (USA only) or mobilehome and mu

Page 15 - Operation - Model H34D

Canadian Heating Products Inc.Langley, BC V4W 4A1Montigo Del Ray Corp.Ferndale, WA 98248XG0130 Rev. 0 - 11/2003

Page 16 - Operation - Model H34D-I

Page 3H34D Gas FireplacePart No. XG0130Installing The Fireplace ShellThe fireplace may be installed in any location that maintains properclearances to

Page 17 - Operation

Page 4H34D Gas FireplacePart No. XG0130Vent InstallationThis section covers the installation of direct venting and terminations.Installation Requirem

Page 18

Page 5H34D Gas FireplacePart No. XG0130Installing Terminations with Built-In FramesInstalling Terminations with MSR Frames12121. Frame the termination

Page 19 - Warranty

Page 6H34D Gas FireplacePart No. XG0130InstallationConverting to Top Vent/ Rear VentH34DL Top VentUse the following instructions to convert an H34DL f

Page 20 - H34D Gas Fireplace

Page 7H34D Gas FireplacePart No. XG0130InstallationAvailable Top Vent ComponentsThe following venting components are available for the H34D TopVent:A

Page 21 - Part No. XG0130

Page 8H34D Gas FireplacePart No. XG0130InstallationHorizontal VentingFigure 12. Typical Top Vent installation. The solid sections can be used invariou

Page 22 - Montigo Del Ray Corp

Page 9H34D Gas FireplacePart No. XG0130InstallationB. Vertical (Through-The-Roof) Installations Vertical Terminations must be installed:• minimum 2&a

Commentaires sur ces manuels

Pas de commentaire