Appendix A - Termination Locations
A = clearance to the termination frame above grade, veranda, porch, deck,
or balcony [16 inches (41 cm) minimum]
B
= clearance to door, or sides and top of window, that may be opened [16
inches (41 cm) minimum for appliances ≤100 000 BTU/H (30kW)]
C
= clearance to bottom of window that may be opened horizontally [36 inches
(92 cm) minimum for appliances ≤100 000 BTU/H (30kW)]
D
= no clearance to permanently closed window when installed with approved
glass penetration termination
E
= clearance to permanently closed window [16 inches 41 cm recommended
to prevent condensation on window]
F
= vertical clearance to ventilated soft located above the termination within a
horizontal distance of 2 feet (61 cm) from the centreline of the termination
[22 inches (56 cm) minimum]
G
= c l e a r a n c e t o u n v e n t i l a t e d s o f f i t [ 1 6 i n c h e s
( 4 1 c m ) m i n i m u m t o n o n - c o m b u s t i b l e s ]
[22 inches (56 cm) minimum to combustibles]
H
= clearance to outside corner [9 inches (23 cm) minimum]
I = clearance to inside corner [12 inches (31 cm) minimum]
J = * not to be installed above a meter/regulator assembly within
40" (103 cm) horizontally from the centreline of the regulator
K
= clearance to service regulator vent outlet [3 feet minimum in the United
States] [*6 feet (1.8 m) minimum in Canada]
L
= clearance to non-mechanical air supply inlet to building or the combustion
air inlet to any other appliance [16 inches (41 cm) minimum for appliances
≤100 000 BTU/H (30kW)]
M
= clearance to mechanical air supply inlet [*6 feet (1.8 m) minimum]
N =
†
clearance above paved sidewalk or a paved driveway located on public
property [*7 feet (2.1 m) minimum]
P
= c l e a r a n c e u n d e r v e r a n d a , p o r c h , d e c k , o r b a l c o n y
[1 6 i n c h e s (4 1 c m ) m i n im u m
‡
to no n - c o m bu s t i b l e s ]
[22 inches (56 cm) minimum
‡
to combustibles]
Q
= clearance above a roof [24 inches (61 cm) minimum]
R = clearanc e to adjacent walls and neighborin g buildings
[18 inches (46 cm) minimum]
S
= c l e a r a n c e f r o m c o r n e r i n r e c e s s e d l o c a t i o n
[12 inches (31 cm) minimum]
T
= m a x i m u m d e p t h i n r e c e s s e d l o c a t i o n
[48 inches (122 cm) minimum]
U
= mi n i m u m w i d t h f o r b a c k w a l l o f r e c e s s e d l o c a t i o n
[24 inches (61 cm) minimum]
V
= no horizontal clearance between the frames of two terminations that
are level.
W
= horizontal clearance between the frames of two terminations that are
not level. [36 inches (92 cm) minimum]
†
a vent shall not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings
‡
only permitted if veranda, porch, deck, or balcony has an open side that
is equal to or greater than the depth of the enclosed area
*
as specied in CGA B149 Installation Codes. Note: local Codes or
Regulations may require different clearance.